Product Introduction

Usage and performance specifications:

Storage tanks for various light oil products used in coking plants, urban gas plants, refineries, and chemical plants. After using a breathing valve in the oil tank, the evaporation loss of oil in the tank can be significantly reduced, and the pressure inside the tank can be automatically adjusted and the ventilation of the oil tank can be improved. Complies with the provisions of the Ministry of Petroleum Industry standard SY7511-87.

Features:

1. The material of the jacket breathing valve is cast steel and stainless steel, with good corrosion resistance.

2. The valve disc and valve sealing ring are made of stainless steel and tetrafluoroethylene materials. Low temperature resistance and good anti freezing performance.

3. This valve is a ventilation device installed on a fixed roof tank to reduce oil evaporation loss and control tank pressure.

4. This valve has high ventilation capacity, low leakage, corrosion resistance, and good frost resistance.

5. It has the characteristics of automatically adjusting the internal and external pressure of oil storage tanks.

6. Simple structure, light weight, easy maintenance, and easy installation.

7. The water pressure test is qualified.

Applicable scope:

Can be used in conjunction with flame arresters.

Set pressure (operating pressure):

Positive pressure:+980pa Negative pressure: -295pa

Performance:

1. Qualified low-temperature and antifreeze resistance: within -40. After operating for 2 hours, the pressure valve disc, vacuum valve disc, and sealing ring showed no deformation and fully met the design requirements.

2. At room temperature of 36. Operate continuously for 72 hours at time C, with 10000 actions. The contact surfaces of the pressure valve disc, vacuum valve disc, and guide rod show no signs of wear or damage, and the guide rod is sensitive to lifting without jamming.

Maintenance and repair:

To ensure that the performance of the jacket breathing valve is fully utilized. The breathing valve should be inspected and maintained within six months.

1. Check if the pressure valve disc and vacuum valve disc move flexibly, and if there is any damage to the contact surface of the guide rod and valve sealing ring.

2. When reinstalling the pressure valve disc, it should be ensured that the contact surface is strict and the guide rod can be lifted and lowered flexibly.

When starting a new valve, the shock absorber of the valve disc should be removed before installation, otherwise the breathing valve will malfunction.

5. Due to humid and sandy weather conditions, when the temperature reaches zero degrees, the storage tank cannot be used for oil release. During emergency production, it is necessary to first open the oil measuring hole and other gas supply products to maintain the safety of the storage tank.

Before the breathing valve can operate normally and feed oil, the oil measuring hole must be opened first